- [99Mo]-Sodium Molybdate Solution (TCM-2)
-
Product Code: TCM-2
- Description: 99Mo as Sodium molybdate solution and Methyl Ethyl Ketone (MEK ) are used for extraction of 99mTc using Solvent Extraction Generator (SEG).
- Specific activity of 99Mo: 6.66 GBq/g – 37 GBq/g
- Activity denominations: 3.7 GBq ( 100 mCi), 5.55 GBq ( 150 mCi), 7.4 GBq (200 mCi), 9.25 GBq (250 mCi)
- Expiry: 1 week
- Supply Frequency: Weekly on Saturday
- Accessories: Each TCM-2 consignment supplied along with Kit comprises of:
1 20g NaOH, 2 3x5g basic alumina 3 100ml DDW 4 250ml MEK 5 Empty autoclaved vial (10x10ml) 6 0.9% NaCl solution (10x10ml) 7 sterile beaker (1x100ml) - Calibration: Monday at 12:00 hrs
Following Accessories (with code) for SEG are available on demand.
- All Glass items solvent extraction generator - TCM-3
- Lead Shield for extraction Assembly - TCM-4
- Hand operated Vacuum pump - TCA-2
- Glass Filtration Assembly - TCA-4
- MEK Solvent (250ml) - TCA-5
Solvent Extraction Generator (SEG)
- [177Lu]-Lutetium Chloride
-
Product Code: LU-2
- Description: Non-sterile 177Lu as [177Lu]-LuCl3 in 0.01-0.1M HCl
- Production method: Neutron activation of enriched 176Lu target
- Radiochemical purity: >99%
- Radionuclidic purity: >99.9%
- Specific activity: >555 GBq/mg on calibration date
- Radioactive concentration: >18.5 GBq/mL
- Application: API for manufacturing 177Lu-labeled RPhs; Not for direct human use
- Availability: Monthly production
- Expiry: 1 week from the calibration date
- Calibration: 2 days
- Storage: Room temperature
- [131-I]- Sodium Iodide
-
Product Code: I-2
- Description: 131I as 131I-NaI in sodium hydroxide solution
- Production method:From 130Te target
- pH:8-11
- Radioactive concentration: >18.5 GBq/mL on calibration date and time
- Availability: Weekly production
- Calibration: 3 or 5 days
- Application: For industrial filter testing.
- Sm-1
-
Product Code: Sm-1
- Description: 153Sm as 153SmCl3 in dil. HCl
- pH: 1-2
- Radioactive concentration: >18.5 GBq/mL at calibration date and time
- Specific activity: >18.5 GBq/mg at calibration date and time
- Availability: Thrice in a month
- Calibration: 3 days