Low Level Check Sources:
Low level check sources are used for checking the efficiency of radiation monitors and instruments. It is also used for energy calibration experiments/studies and as a tracer in well logging.
Note*- Source supplied under this category are not absolutely calibrated sources and hence no calibration certificate will be issued.
Procedure to procure low-level check sources from BRIT:
The application is to be submitted (separate application for each product code and quantity) in duly filled in the A-3 form (available in our web site http://www.britatom.gov.in/) along with specific source procurement authorization (NOC) obtained from AERB, through the e-Licensing of Radiation Applications (eLORA) System.
Points to be noted while applying for AERB NOC from eLORA System
- Login to the Sealed source profile.
- Under regulatory -> form sealed source -> Application for procurement.
- Select the product as per the product models are given in the following list by confirming the make as BRIT and supplier as BRIT.
- While filling the application the purpose of the use is to be mentioned as “check source ”.
- Beta Reference Sources-BRS*
-
Sr.No. Product Code Radiation Sources 1 BRS-2 (Co-60) 2 BRS-3 (Pb-210-Bi-210) 3 BRS-4 (Sr-90-Y-90) 4 BRS-5 (Tl-204) 5 BRS-7 (Ca-45) 6 BRS-8 (P-32) 7 BRS-9 (Pm-147) 8 DS Dummy sources - *BRS – Evaporated ultrasonically sealed Beta source at the centre of 25 mm dia X 5 mm (OD) thick plastic disc and covered with 3mg/cm2 mm thick aluminised mylar film. Active diameter:6mm.
Maximum Strength - 1MBq
- Conversion Electron Reference Sources
-
Sr.No. Product Code Radiation Sources 1 BAC-1 (Ba-133) 2 CEC-1 (Ce-141) 3 CSC-1 (Cs-137) 4 COC-1 (Co-57) 5 SNC-1 (Sn-113) Conversion electron sandwiched evaporated source between the suitable thickness of aluminized mylar film rings: mounted on 25 mm dia X 5 mm thick (OD) plastic disc, adhesive (epoxy) sealed source. Active dia: ~6 mm at the center.
Maximum Strength - 1MBq
- Nuclear Medicine Reference Sources
-
Sr.No. Product Code Radiation Sources 1 COSM-3 (Co-57) - COSM-3 Cobalt-57 Spot Marker Source (Anatomical Markers)
- Evaporated gamma point source adsorbed on ceramic bead: mounted at the center of 25 mm dia X 5 mm thick (OD) color-coded plastic disc, adhesive (epoxy) sealed sources. Active dia: ~ 2 mm.
Maximum Strength - 1MBq
- Gamma Reference Source – Disc Type
-
Sr.No. Product Code Radiation Sources 1 GDS-1 (Ba-133) 2 GDS-2 (Cs-137) 3 GDS-3 (Co-57) 4 GDS-4 (Co-60) 5 GDS-5 (Mn-54) 6 GDS-6 (Simulated I-131) 7 GDS-7 (Na-22) 8 GDS-8 (Cr-51) 9 GDS-9 (Hg-203) 10 GDS-10 (Zn-65) 11 GDS-11 (I-131) 12 GDS-12 (Eu-152) GDS – Gamma Disc Source. Evaporated ultrasonically sealed gamma source at the center of 25 mm dia X 5 mm thick (OD) color-coded plastic disc and covered with 1mm thick plastic lid.Active dia: ~6 mm
Maximum Strength - 1MBq
- Gamma Reference Sources – Rod Type
-
Sr.No. Product Code Radiation Sources 1 GRS-1 (Ba-133) 2 GRS-2 (Cs-137) 3 GRS-3 (Co-57) 4 GRS-4 (Co-60) 5 GRS-5 (Mn-54) 6 GRS-6 (Simulated I-131) 7 GRS-7 (Na-22) 8 GRS-8 (Cr-51) 9 GRS-9 (Hg-203) 10 GRS-10 (Zn-65) 11 GRS-11 (I-131) 12 GRS-12 (Eu-152) GRS – Gamma Rod Source.Evaporated source at the end of 12 mm dia X 100 mm length (OD) colour coded plastic rod: adhesive (epoxy) sealed source. Active dia: ~6 mm
Maximum Strength - 1MBq
- X-RAY & Low Energy Gamma Reference Sources
-
Sr.No. Product Code Radiation Sources 1 BAX-1 (Ba-133) 2 COX-1 (Co-57) 3 FEX-1 (Fe-55) 4 IOX-1 (I-125) 5 SNX-1 (Sn-113) X-Ray & Low Energy Gamma source at the centre of 25 mm dia X 5 mm thick (OD) plastic disc: adhesive (epoxy) evaporated sealed source covered with suitable Mylar film window. Active dia: ~6mm.
Maximum Strength - 1MBq
- Alpha Reference Sources
-
Sr.No. Product Code Product Description 1 AMS-1 Electrodeposited 241Americium α reference source upto 0.1µCi 2 PUS-1 Pu239 α reference source upto 0.1 µCi 3 PUS-2 Pu239 deposited by electroplating on SS plate of dim 0.15 cm x 10 cm With strength upto 0.1 µCi - Electrodeposited on S.S. planchette of 25 mm dia x 5 mm thick.
- Active dimension: 10 mm dia
Maximum Strength - 1µCi
- Beta & Gamma Reference Sources Kits - Disc Type
-
Sr.No. Product Code Product Description 1 BDB-1 Box containing a set of 4 Beta Disc(Pm-147, Co-60, Tl-204, Sr-90)Sources and one Dummy Source 2 GDB-1 Box containing a set of 5 Gamma Disc Sources and one Dummy Source, Any five of the following sources: Ba-133, Cs-137, Co-57, Co-60, Na-22, Mn-54 - Beta Disc Source: Beta Source at the centre of 25 mm dia x 5 mm (OD) thick plastic disc source holder with suitable window
- Gamma Disc Source: Evaporated source at the centre of 25 mm dia x 5 mm thick (OD) colour coded plastic disc adhesive (epoxy) sealed sources. Active dia: ~ 6 mm.
- Packing, forwarding & freight charges will be levied at actuals.
Maximum Strength - 1MBq
- Beta,Gamma Hand Monitor Radioactive Spread Sources
-
Sr.No. Product Code Product Description 1 ASR 1 Beta, Gamma hand monitor radioactive spread sources of Sr90 – Y90 (up to 4000 dpm) 2 ASR 2 Beta, Gamma hand monitor radioactive spread sources of Sr90 – Y90 (> 4000 dpm) Maximum Strength - 1MBq
- Low Level Industrial Sources
-
Sr.No. Product Code Radiation Sources 1 COSM-4 Electrodeposited Cobalt-57 2 ENI-2 Electrodeposited Nickle-63 3 EFE-1 Electrodeposited Ferrum-55 4 ECD-1 Electrodeposited Cadmium-109 5 BSTM-1 Electrodeposited Tl-204 6 PMDM-1 Electrodeposited Pm-147 7 PMDM-2 Beta Source Pm-147 8 ENI-1 Electrodeposited Nickle-63 TLD sources 9 PCO-1 Polymer radioactive film Cobalt-60 (“PIP” TAG sources) 10 EBAM-1 Electrodeposited Ba-133 11 ECOI-1 Electrodeposited Co-60 All the above sources are Electrodeposited sources except C0-60 “PIP” TAG sources.
Dimensions: # Co-60 “PIP” TAG sources are Evaporated thin polymer sources with the activity distributed uniformly. + Packing, forwarding & freight charges will be extra as applicable.
Maximum Strength - 1MBq
Contact :
Jacob Sebastian
DGM,Sales & Marketing (S&M) ,Board of Radiation & Isotope Technology
Project House, V.N. Purav Marg, Anushakti Nagar, Mumbai 400 094